123 Sample Street

Anytown, WI, 12345

September 1st, 2020

INSPECTED BY

Joe Young

PREPARED FOR

Sample Client

Estimated Square Feet

2489

In Attendance

Client's Agent
Client

Inspection Fee

$400

Number of Bathrooms

Three ½

Number of Bedrooms

Four

Number of Stories

One

Occupancy

Furnished
Occupied

Style

Ranch

Type of Building

Single Family

Weather Conditions

Recent Rain
Dry
Clear

Year Built

2003

General Information

This confidential report is prepared exclusively for Sample Client . The inspection and report are in no way a guarantee or warranty, express or implied, regarding the future use, operability, habitability or suitability of the home/building or its components. Kettle Moraine Home Inspections, LLC is not responsible for its use or misinterpretation by third parties, and third parties who rely on it in any way do so at their own risk and release Kettle Moraine Home Inspections, LLC (including employees and business entities) from any liability whatsoever.

IMPORTANT NOTE- PLEASE READ : There is a Summary available and is only provided to allow the reader a brief overview of the report. The Summary is not encompassing. Reading the summary alone is not a substitute for reading the report in entirety. The entire Inspection Report, including the Standards of Practice, Limitations, Exceptions, Exclusions, Scope of Inspection and Pre-Inspection Agreement must be carefully read to fully assess the findings of the inspection.

It is recommended that any deficiencies and the components/systems related to these deficiencies noted in the report be evaluated/inspected and repaired as needed by licensed contractors/professionals PRIOR TO THE CLOSE OF ESCROW. Further evaluation PRIOR to the close of escrow is recommended so a properly licensed professional can evaluate our concerns further and inspect the remainder of the system or component for additional concerns that may be outside our area of expertise or the scope of our inspection. Please call our office for any clarifications or further questions.

Scope of Work

All components designated for inspection in the InterNACHI Standards of Practice are inspected, except as may be noted in the "Limitations of Inspection" sections within this report. The complete InterNACHI Standards of Practice can be viewed at http://nachi.org/sop . Not all improvements will be identified during this inspection. Unexpected repairs should still be anticipated. The inspection should not be considered a guarantee or warranty of any kind. Please refer to the pre-inspection contract for a full explanation of the scope of the inspection.

Definitions and Scope

1.1. A home inspection is a non-invasive, visual examination of the accessible areas of a residential property (as delineated below), performed for a fee, which is designed to identify defects within specific systems and components defined by these Standards that are both observed and deemed material by the inspector. The scope of work may be modified by the Client and Inspector prior to the inspection process.

` I. The home inspection is based on the observations made on the date of the inspection, and not a prediction of future conditions.

II. The home inspection will not reveal every issue that exists or ever could exist, but only those material defects observed on the date of the inspection.`

1.2. A material defect is a specific issue with a system or component of a residential property that may have a significant, adverse impact on the value of the property, or that poses an unreasonable risk to people. The fact that a system or component is near, at, or beyond the end of its normal, useful life is not, in itself, a material defect.

1.3. A home inspection report shall identify, in written format, defects within specific systems and components defined by these Standards that are both observed and deemed material by the inspector. Inspection reports may include additional comments and recommendations.

Limitations, Exceptions & Exclusions

2.1. Limitations:

I. An inspection is not technically exhaustive.

II. An inspection will not identify concealed or latent defects. III. An inspection will not deal with aesthetic concerns, or what could be deemed matters of taste, cosmetic defects, etc. IV. An inspection will not determine the suitability of the property for any use. V. An inspection does not determine the market value of the property or its marketability. VI. An inspection does not determine the insurability of the property. VII. An inspection does not determine the advisability or inadvisability of the purchase of the inspected property. VIII. An inspection does not determine the life expectancy of the property or any components or systems therein. IX. An inspection does not include items not permanently installed. X. This Standards of Practice applies to properties with four or fewer residential units and their attached garages and carports.

2.2. ++Exclusions++:

I. The inspector is not required to determine:

A. property boundary lines or encroachments. B. the condition of any component or system that is not readily accessible. C. the service life expectancy of any component or system. D. the size, capacity, BTU, performance or efficiency of any component or system. E. the cause or reason of any condition. F. the cause for the need of correction, repair or replacement of any system or component. G. future conditions. H. compliance with codes or regulations. I. the presence of evidence of rodents, birds, bats, animals, insects, or other pests. J. the presence of mold, mildew or fungus. K. the presence of airborne hazards, including radon. L. the air quality. M. the existence of environmental hazards, including lead paint, asbestos or toxic drywall. N. the existence of electromagnetic fields. O. any hazardous waste conditions. P. any manufacturers' recalls or conformance with manufacturer installation, or any information included for consumer protection purposes. Q. acoustical properties. R. correction, replacement or repair cost estimates. S. estimates of the cost to operate any given system.

II. The inspector is not required to operate:

A. any system that is shut down. B. any system that does not function properly. C. or evaluate low-voltage electrical systems, such as, but not limited to: 1. phone lines; 2. cable lines; 3. satellite dishes; 4. antennae; 5. lights; or 6. remote controls. D. any system that does not turn on with the use of normal operating controls. E. any shut-off valves or manual stop valves. F. any electrical disconnect or over-current protection devices. G. any alarm systems. H. moisture meters, gas detectors or similar equipment. III. The inspector is not required to: A. move any personal items or other obstructions, such as, but not limited to: throw rugs, carpeting, wall coverings, furniture, ceiling tiles, window coverings, equipment, plants, ice, debris, snow, water, dirt, pets, or anything else that might restrict the visual inspection. B. dismantle, open or uncover any system or component. C. enter or access any area that may, in the inspector's opinion, be unsafe. D. enter crawlspaces or other areas that may be unsafe or not readily accessible. E. inspect underground items, such as, but not limited to: lawn-irrigation systems, or underground storage tanks (or indications of their presence), whether abandoned or actively used. F. do anything that may, in the inspector's opinion, be unsafe or dangerous to him/herself or others, or damage property, such as, but not limited to: walking on roof surfaces, climbing ladders, entering attic spaces, or negotiating with pets. G. inspect decorative items. H. inspect common elements or areas in multi-unit housing. I. inspect intercoms, speaker systems or security systems. J. offer guarantees or warranties. K. offer or perform any engineering services. L. offer or perform any trade or professional service other than a home inspection. M. research the history of the property, or report on its potential for alteration, modification, extendibility or suitability for a specific or proposed use for occupancy. N. determine the age of construction or installation of any system, structure or component of a building, or differentiate between original construction and subsequent additions, improvements, renovations or replacements. O. determine the insurability of a property. P. perform or offer Phase 1 or environmental audits. Q. inspect any system or component that is not included in these Standards.

1 · Attic, Insulation & Ventilation

Attic, Insulation & Ventilation

I. The inspector shall inspect: A. insulation in unfinished spaces, including attics, crawlspaces and foundation areas; B. ventilation of unfinished spaces, including attics, crawlspaces and foundation areas; and C. mechanical exhaust systems in the kitchen, bathrooms and laundry area. II. The inspector shall describe: A. the type of insulation observed; and B. the approximate average depth of insulation observed at the unfinished attic floor area or roof structure. III. The inspector shall report as in need of correction: A. the general absence of insulation or ventilation in unfinished spaces. IV. The inspector is not required to: A. enter the attic or any unfinished spaces that are not readily accessible, or where entry could cause damage or, in the inspector's opinion, pose a safety hazard. B. move, touch or disturb insulation. C. move, touch or disturb vapor retarders. D. break or otherwise damage the surface finish or weather seal on or around access panels or covers. E. identify the composition or R-value of insulation material. F. activate thermostatically operated fans. G. determine the types of materials used in insulation or wrapping of pipes, ducts, jackets, boilers or wiring. H. determine the adequacy of ventilation.

Attic Insulation

Insulation Type

Blown
Fiberglass

1.1 · Insulation Depth

Insulation was not installed evenly. It was measured at a depth of 12 inches where the inspector was able to reach but the depth varies around the attic. Recommend a licensed and qualified contractor install insulation evenly at the proper depth.
Repair Recommended

Exhaust Systems

Exhaust Fans

Bathroom Exhaust Fan - Operable
Kitchen Exhaust Fan - Operable

1.2 · Dryer Vent

Dryer vent appears clogged with lint. Recommend cleaning dryer ductwork on a regular basis for fire prevention and operating efficiency of the dryer.
Safety Issue

Roof Structure

Material

OSB
Wood

Type

Gable

Attic Inspection

Roof Structure

Trusses

Viewed From

Access limited to viewing from access hatch

1.3 · Viewed From

The inspection of the attic was limited to viewing from the access hatch. The loose fill insulation covering the ceiling joists/lower portion of the truss cords prevented the inspector from safely entering the space fully. Due to this limitation, there may exist defects in the roof/attic structure that the inspector was not able to see.
Limitations

Ventilation

Ventilation Type

Roof Jacks and Soffit Vents

2 · Built-in Appliances

Built-in Microwave

Operable

Yes

Dishwasher

Operable

Yes

Garbage Disposal

Operable

Yes

Range/Oven/Cooktop

Operable

Yes

General

2.1 · Note

Appliances are only tested for operation, working or not. Quality or extent of operation is not part of the home inspection.
Limitations

Refrigerator

Operable

Yes

3 · Roof

Roof

I. The inspector shall inspect from ground level or the eaves: A. the roof-covering materials; B. the gutters; C. the downspouts; D. the vents, flashing, skylights, chimney, and other roof penetrations; and E. the general structure of the roof from the readily accessible panels, doors or stairs. II. The inspector shall describe: A. the type of roof-covering materials. III. The inspector shall report as in need of correction: A. observed indications of active roof leaks. IV. The inspector is not required to: A. walk on any roof surface. B. predict the service life expectancy. C. inspect underground downspout diverter drainage pipes. D. remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces. E. move insulation. F. inspect antennae, satellite dishes, lightning arresters, de-icing equipment, or similar attachments. G. walk on any roof areas that appear, in the inspectors opinion, to be unsafe. H. walk on any roof areas if doing so might, in the inspector's opinion, cause damage. I. perform a water test. J. warrant or certify the roof. K. confirm proper fastening or installation of any roof-covering material.

Flashings

Material

Aluminum

3.1 · Material

Flashings were visible and no adverse conditions were observed at the time of the inspection.
General Information

Roof Drainage Systems

Gutter Material

Aluminum

3.2 · Debris

Gutters should be cleaned on a regular basis to ensure proper functioning of the system.
Maintenance Item

3.3 · Downspouts Drain Near House

One or more downspouts discharge into sub surface drains. Termination locations for these sub surface drains were not observed at the time of the inspection. The condition of underground pipes or locations of their termination points (if any) is not determined as part of this inspection. It is recommended that the client verify the termination points of all subsurface drains prior to closing.
Further Evaluation Needed

3.4 · Downspouts Drain Near House

One or more downspouts drain too close to the homes foundation. This can result in excessive moisture in the soil at the foundation, which can lead to foundation/structural movement. Recommend a qualified contractor adjust downspout extensions to drain at least 6 feet from the foundation.
Repair Recommended

General

Inspection Method

Ladder at eaves

Roof Type/Style

Gable
Roof Slope = Steep

3.5 · Inspection Method

Roof inspection limited by slope of roof and wet shingles. Roof was observed from ladder at eaves at multiple locations and the ground.
Limitations

Coverings

Material

1 Layer
Asphalt

3.6 · Condition

No adverse conditions were observed regarding the house's roof covering.
General Information

Valleys

Condition

No adverse conditions observed

Material

Aluminum
Asphalt

4 · Fireplace

Fireplace

I. The inspector shall inspect:readily accessible and visible portions of the fireplaces and chimneys;lintels above the fireplace openings;damper doors by opening and closing them, if readily accessible and manually operable; andcleanout doors and frames.II. The inspector shall describe:the type of fireplace.III. The inspector shall report as in need of correction:evidence of joint separation, damage or deterioration of the hearth, hearth extension or chambers;manually operated dampers that did not open and close;the lack of a smoke detector in the same room as the fireplace;the lack of a carbon-monoxide detector in the same room as the fireplace; andcleanouts not made of metal, pre-cast cement, or other non-combustible material.IV. The inspector is not required to:inspect the flue or vent system.inspect the interior of chimneys or flues, fire doors or screens, seals or gaskets, or mantels.determine the need for a chimney sweep.operate gas fireplace inserts.light pilot flames.determine the appropriateness of any installation.inspect automatic fuel-fed devices.inspect combustion and/or make-up air devices.inspect heat-distribution assists, whether gravity-controlled or fan-assisted.ignite or extinguish fires.determine the adequacy of drafts or draft characteristics.move fireplace inserts, stoves or firebox contents.perform a smoke test.dismantle or remove any component.perform a National Fire Protection Association (NFPA)-style inspection.perform a Phase I fireplace and chimney inspection.

General

Mantel

Secure

Type

Gas

4.1 · Type

Power and gas supply were turned off to gas fireplace at the time of the inspection and the unit could not be tested for proper function. It is recommended that the fireplace be evaluated for proper operation prior to closing once the gas and power are supplied to the unit.
Further Evaluation Needed

5 · Exterior

Exterior

I. The inspector shall inspect: A. the exterior wall-covering materials, flashing and trim; B. all exterior doors; C. adjacent walkways and driveways; D. stairs, steps, stoops, stairways and ramps; E. porches, patios, decks, balconies and carports; F. railings, guards and handrails; G. the eaves, soffits and fascia; H. a representative number of windows; and I. vegetation, surface drainage, retaining walls and grading of the property, where they may adversely affect the structure due to moisture intrusion. II. The inspector shall describe: A. the type of exterior wall-covering materials. III. The inspector shall report as in need of correction: A. any improper spacing between intermediate balusters, spindles and rails. IV. The inspector is not required to: A. inspect or operate screens, storm windows, shutters, awnings, fences, outbuildings, or exterior accent lighting. B. inspect items that are not visible or readily accessible from the ground, including window and door flashing. C. inspect or identify geological, geotechnical, hydrological or soil conditions. D. inspect recreational facilities or playground equipment. E. inspect seawalls, breakwalls or docks. F. inspect erosion-control or earth-stabilization measures. G. inspect for safety-type glass. H. inspect underground utilities. I. inspect underground items. J. inspect wells or springs. K. inspect solar, wind or geothermal systems. L. inspect swimming pools or spas. M. inspect wastewater treatment systems, septic systems or cesspools. N. inspect irrigation or sprinkler systems. O. inspect drainfields or dry wells. P. determine the integrity of multiple-pane window glazing or thermal window seals.

Decks, Balconies, Porches & Steps

Appurtenance

Covered Porch
Deck with Steps

Material

Wood

5.1 · Railing Unsafe

The deck railing was observed to be loose and not properly secured to the deck. Proper attachment of the railing is necessary for safety. Recommend a qualified deck contractor repair as needed.
Safety Issue

5.2 · Railing Unsafe

The handrail for the deck stairs is not graspable. A graspable handrail is necessary for safety. Recommend a qualified deck contractor repair as needed.
Safety Issue

5.3 · Stoops

Step from the garage service door to the outside has a higher than normal riser height. This can be a safety issue and correction is recommended.
Safety Issue

5.4 · Deck - Rotted Boards

One or more deck joists are cracked. Recommend a qualified contractor replace as needed.
Safety Issue

5.5 · Deck - Water Sealant Required

Deck is showing signs of weathering and/or water damage. Recommend water sealant/weatherproofing be applied.
Maintenance Item

5.6 · Improper Deck Construction Practices

Improper beam attachment to posts was observed. Recommend a licensed and qualified deck contractor evaluate and correct as needed.
Repair Recommended

5.7 · Improper Deck Construction Practices

No visible footings were are observed at the time of the inspection and posts are in contact with soil. Wood in direct contact with the soil is prone to premature deterioration. It is recommended that the presence of footings be verified and a licensed and qualified deck contractor repair as needed
Repair Recommended

5.8 · Improper Deck Construction Practices

Deck joists are not mechanically fastened to the beam. Recommend repair by a licensed and qualified contractor.
Repair Recommended

5.9 · Ledger Board Improperly Installed

The ledger board is not properly attached to the building. This can cause the deck to pull away from the building and possibly collapse. Recommend that the deck and/or ledger board be properly attached to the building by a licensed and qualified contractor.
Safety Issue

Siding, Flashing & Trim

Siding Material

Vinyl

5.10 · Caulking

Caulk around windows, doors, where dissimilar materials meet and other penetrations should be maintained. Recommend re-caulking areas where openings exist or were existing caulk is failing.
Maintenance Item

5.11 · Damage

Siding and trim were damaged in some locations. Recommend repair of these areas by a qualified contractor and monitoring for any areas that being to allow moisture intrusion.
Repair Recommended

5.12 · Siding Improper Installation

The siding is installed too close to the roof covering. There should be some space between the siding and the roof covering, typically about an inch. Due to the installation method, the existence of continuous step flashing cannot be confirmed.
Limitations

5.13 · Trim - Chipped/Peeling Paint

Some areas of trim were observed to have chipped and/or peeling paint. It is recommended that the trim be scraped and repainted to preserve the integrity of the wood.
Repair Recommended

5.14 · Ground Clearance

Inadequate clearance between siding and ground. Recommend a minimum ground clearance between bottom of siding and ground of 6 to 8 inches. Siding in contact with the ground or soil is a serious concern because that condition can provide direct access for wood destroying insects.
Repair Recommended

Vegetation, Grading, Drainage & Retaining Walls

5.15 · Vegetation In Contact With Building

Vegetation is in contact with the building and can contribute to moisture issues as well as insect access to the home. It is recommended that all vegetation be trimmed back at least 12 inches from the home.
Maintenance Item

5.16 · Retaining wall movement

Some retaining wall stones appear to be loose and/or out of place. Recommend continued monitoring for future movement and repair as needed.
General Information

Walkways, Patios & Driveways

Driveway Material

Concrete

5.17 · Driveway Cracking - Minor

Minor cosmetic cracks observed, which may indicate movement in the soil. Recommend monitor and/or have a licensed and qualified contractor patch/seal.
Repair Recommended

5.18 · Walkway obstructed

Landscaping is currently blocking the service walk. It is recommended that the landscaping be trimmed back to keep the walkway clear.
Maintenance Item

6 · Garage

Garage Door

Material

Metal

Type

Automatic

6.1 · Auto Reverse Sensor Not Working

The auto reverse sensor was not responding at time of inspection. This is a safety hazard to children and pets. Recommend a qualified garage door contractor evaluate and repair/replace.
Safety Issue

Garage Roof

Material

Same as house

Garage Door Opener

6.2 · Operation

The garage door operated properly when using the normal operating controls.
General Information

General

6.3 · Visibility

The inspection of the garage was limited due to the possessions of the homeowner.
Limitations

Occupant Door (From garage to inside of home)

6.4 · Not Self-closing

The door from the garage to the home should have self-closing hinges to help prevent spread of a fire to living space. Recommend a licensed and qualified contractor install self-closing hinges.
Safety Issue

7 · Basement, Foundation, Crawlspace & Structure

Basement, Foundation, Crawlspace & Structure

I. The inspector shall inspect: A. the foundation; B. the basement; C. the crawlspace; and D. structural components. II. The inspector shall describe: A. the type of foundation; and B. the location of the access to the under-floor space. III. The inspector shall report as in need of correction: A. observed indications of wood in contact with or near soil; B. observed indications of active water penetration; C. observed indications of possible foundation movement, such as sheetrock cracks, brick cracks, out-of-square door frames, and unlevel floors; and D. any observed cutting, notching and boring of framing members that may, in the inspector's opinion, present a structural or safety concern. IV. The inspector is not required to: A. enter any crawlspace that is not readily accessible, or where entry could cause damage or pose a hazard to him/herself. B. move stored items or debris. C. operate sump pumps with inaccessible floats. D. identify the size, spacing, span or location or determine the adequacy of foundation bolting, bracing, joists, joist spans or support systems. E. provide any engineering or architectural service. F. report on the adequacy of any structural system or component.

Basements & Crawlspaces

7.1 · High Moisture Levels

Several dehumidifiers were in use at the time of the inspection. This may indicate a higher than normal humidity level in the basement. It is recommended that the client ask the seller about moisture levels in the basement.
Further Evaluation Needed

7.2 · Drainage

There is a sump pump pit present in the basement, however there is no sump pump currently installedl
General Information

Floor Structure

Basement/Crawlspace Floor

Concrete

Material

Concrete
Wood Beams

Sub-floor

Plywood

Foundation

Columns

Steel

Material

Concrete

7.3 · Foundation Exterior

The above grade foundation is covered by insulation and flashing. The exterior of the foundation was not visible and not evaluated.
Limitations

8 · Heating

Heating

I. The inspector shall inspect: A. the heating system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the heating system; B. the energy source; and C. the heating method. III. The inspector shall report as in need of correction: A. any heating system that did not operate; and B. if the heating system was deemed inaccessible. IV. The inspector is not required to: A. inspect or evaluate the interior of flues or chimneys, fire chambers, heat exchangers, combustion air systems, fresh-air intakes, humidifiers, dehumidifiers, electronic air filters, geothermal systems, or solar heating systems. B. inspect fuel tanks or underground or concealed fuel supply systems. C. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the heating system. D. light or ignite pilot flames. E. activate heating, heat pump systems, or other heating systems when ambient temperatures or other circumstances are not conducive to safe operation or may damage the equipment. F. override electronic thermostats. G. evaluate fuel quality. H. verify thermostat calibration, heat anticipation, or automatic setbacks, timers, programs or clocks.

Distribution Systems

Ductwork

Metal duct
Non-insulated

Equipment

Brand

Ruud

Energy Source

Gas

Heat Exchanger

Not Visible
Sealed

Heat Type

Forced Air
Gas-Fired Heat

8.1 · Brand

Based on the information from the data tag, the unit was manufactured in 2003 and is approximately 17 years old. A replacement should be budgeted for.
General Information

8.2 · Brand

Brand and data tag information available.
General Information

8.3 · Needs Servicing/Cleaning

Furnace should be cleaned and serviced annually. Recommend a licensed and qualified HVAC contractor clean, service and certify furnace.
Maintenance Item

8.4 · Filter Dirty

The furnace filter is dirty. It is recommended that the filter be changed every month.
Maintenance Item

Normal Operating Controls

Shut Off Switch

Present

Thermostat Location

First floor hallway

Presence of Installed Heat Source in Each Room

Heat source present in all rooms

Heat source present in all rooms

9 · Cooling

Cooling

I. The inspector shall inspect: A. the cooling system, using normal operating controls. II. The inspector shall describe: A. the location of the thermostat for the cooling system; and B. the cooling method. III. The inspector shall report as in need of correction: A. any cooling system that did not operate; and B. if the cooling system was deemed inaccessible. IV. The inspector is not required to: A. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the cooling system. B. inspect portable window units, through-wall units, or electronic air filters. C. operate equipment or systems if the exterior temperature is below 65 Fahrenheit, or when other circumstances are not conducive to safe operation or may damage the equipment. D. inspect or determine thermostat calibration, cooling anticipation, or automatic setbacks or clocks. E. examine electrical current, coolant fluids or gases, or coolant leakage.

Cooling Equipment

Brand

Ruud

Energy Source/Type

Central Air Conditioner
Electric

Location

Exterior West

Maximum Fuse/Breaker Rating

Breaker size installed 20 amp
Max allowed breaker size 25 amp

Power Shut Off

Exterior disconnect present

9.1 · Air Flow Restricted

Air flow to the air conditioner condenser was restricted. This may result in inefficient operation. Recommend cleaning dirt and/or debris from unit.
Maintenance Item

9.2 · Insulation Missing or Damaged

Missing or damaged insulation on refrigerant line can cause energy loss and condensation. Recommend repair by a licensed and qualified contractor.
Repair Recommended

9.3 · Brand

Based on the data tag, the unit was manufactured in 2003 and is approximately 17 years old. It is recommended that a new unit be budgeted for.
General Information

9.4 · Brand

Brand information
General Information

9.5 · Power Shut Off

Caution - an insect nest was observed inside the housing for the exterior A/C disconnect. Recommend removal of nest by a licensed and qualified contractor for safety.
Maintenance Item

Distribution System

Configuration

Central

Presence of Installed Cooling Source in Each Room

Cooling source present

Cooling source present in all rooms

10 · Electrical

Electrical

I. The inspector shall inspect: A. the service drop; B. the overhead service conductors and attachment point; C. the service head, gooseneck and drip loops; D. the service mast, service conduit and raceway; E. the electric meter and base; F. service-entrance conductors; G. the main service disconnect; H. panelboards and over-current protection devices (circuit breakers and fuses); I. service grounding and bonding; J. a representative number of switches, lighting fixtures and receptacles, including receptacles observed and deemed to be arc-fault circuit interrupter (AFCI)-protected using the AFCI test button, where possible; K. all ground-fault circuit interrupter receptacles and circuit breakers observed and deemed to be GFCIs using a GFCI tester, where possible; and L. smoke and carbon-monoxide detectors. II. The inspector shall describe: A. the main service disconnect's amperage rating, if labeled; and B. the type of wiring observed. III. The inspector shall report as in need of correction: A. deficiencies in the integrity of the serviceentrance conductors insulation, drip loop, and vertical clearances from grade and roofs; B. any unused circuit-breaker panel opening that was not filled; C. the presence of solid conductor aluminum branch-circuit wiring, if readily visible; D. any tested receptacle in which power was not present, polarity was incorrect, the cover was not in place, the GFCI devices were not properly installed or did not operate properly, evidence of arcing or excessive heat, and where the receptacle was not grounded or was not secured to the wall; and E. the absence of smoke detectors. IV. The inspector is not required to: A. insert any tool, probe or device into the main panelboard, sub-panels, distribution panelboards, or electrical fixtures. B. operate electrical systems that are shut down. C. remove panelboard cabinet covers or dead fronts. D. operate or re-set over-current protection devices or overload devices. E. operate or test smoke or carbon-monoxide detectors or alarms F. inspect, operate or test any security, fire or alarms systems or components, or other warning or signaling systems. G. measure or determine the amperage or voltage of the main service equipment, if not visibly labeled. H. inspect ancillary wiring or remote-control devices. I. activate any electrical systems or branch circuits that are not energized. J. inspect low-voltage systems, electrical de-icing tapes, swimming pool wiring, or any timecontrolled devices. K. verify the service ground. L. inspect private or emergency electrical supply sources, including, but not limited to: generators, windmills, photovoltaic solar collectors, or battery or electrical storage facility. M. inspect spark or lightning arrestors. N. inspect or test de-icing equipment. O. conduct voltage-drop calculations. P. determine the accuracy of labeling. Q. inspect exterior lighting.

Branch Wiring Circuits, Breakers & Fuses

Branch Wire 15 and 20 AMP

Copper

Wiring Method

Non Metalic Sheathed Cable

GFCI & AFCI

10.1 · No GFCI Protection Installed

The laundry room receptacle serving the washing machine was missing GFCI protection. GFCI receptacles are recommended in all wet/damp locations for safety. Recommend receptacles be replaced with receptacles providing GFCI protection by a licensed and qualified contractor.
Safety Issue

10.2 · GFCI wired in series

The receptacle located in the hall bathroom is GFCI protected but it is wired to the GFCI outlet in the master bathroom. If the hall bathroom receptacle experiences a ground fault, the outlet can only be reset using the button located on the GFCI receptacle in the master bathroom.
General Information

10.3 · GFCI receptacle not tested

Some GFCI receptacles were not tested for proper operation as occupants electrical items were currently plugged into them.
Limitations

Lighting Fixtures, Switches & Receptacles

10.4 · Inoperable Receptacle

One or more receptacles was observed to be inoperable at the time of the inspection. Recommend repair by a licensed and qualified contractor.
Repair Recommended

Service Entrance Conductors

Electrical Service Conductors

120/240 Volts
Aluminum
Below Ground

Smoke Detectors

10.5 · Inappropriate Location

No smoke detector was observed in the room with the gas fireplace. An additional smoke detector in this location is recommended for safety.
Safety Issue

Main & Subpanels, Service & Grounding, Main Overcurrent Device

Main Panel Location

Basement
Closet

Panel Capacity

200 AMP

Panel Manufacturer

Cutler Hammer

Panel Type

Circuit Breaker

10.6 · Main Panel Location

Panel condition
General Information

10.7 · Main Panel Location

The main breaker panel is located inside a closet in the basement. The clearance to the panel is inadequate to safely access and service the panel.
Safety Issue

10.8 · Service Entry

Meter located on west side of home.
General Information

Carbon Monoxide Detectors

10.9 · Inappropriate Location

No carbon monoxide detector was observed in the room with the gas fireplace. An additional carbon monoxide detector in this location is recommended for safety.
Safety Issue

11 · Plumbing

Plumbing

I. The inspector shall inspect: A. the main water supply shut-off valve; B. the main fuel supply shut-off valve; C. the water heating equipment, including the energy source, venting connections, temperature/pressure-relief (TPR) valves, Watts 210 valves, and seismic bracing; D. interior water supply, including all fixtures and faucets, by running the water; E. all toilets for proper operation by flushing; F. all sinks, tubs and showers for functional drainage; G. the drain, waste and vent system; and H. drainage sump pumps with accessible floats. II. The inspector shall describe: A. whether the water supply is public or private based upon observed evidence; B. the location of the main water supply shut-off valve; C. the location of the main fuel supply shut-off valve; D. the location of any observed fuel-storage system; and E. the capacity of the water heating equipment, if labeled. III. The inspector shall report as in need of correction: A. deficiencies in the water supply by viewing the functional flow in two fixtures operated simultaneously; B. deficiencies in the installation of hot and cold water faucets; C. mechanical drain stops that were missing or did not operate if installed in sinks, lavatories and tubs; and D. toilets that were damaged, had loose connections to the floor, were leaking, or had tank components that did not operate. IV. The inspector is not required to: A. light or ignite pilot flames. B. measure the capacity, temperature, age, life expectancy or adequacy of the water heater. C. inspect the interior of flues or chimneys, combustion air systems, water softener or filtering systems, well pumps or tanks, safety or shut-off valves, floor drains, lawn sprinkler systems, or fire sprinkler systems. D. determine the exact flow rate, volume, pressure, temperature or adequacy of the water supply. E. determine the water quality, potability or reliability of the water supply or source. F. open sealed plumbing access panels. G. inspect clothes washing machines or their connections. H. operate any valve. I. test shower pans, tub and shower surrounds or enclosures for leakage or functional overflow protection. J. evaluate the compliance with conservation, energy or building standards, or the proper design or sizing of any water, waste or venting components, fixtures or piping. K. determine the effectiveness of anti-siphon, backflow prevention or drain-stop devices. L. determine whether there are sufficient cleanouts for effective cleaning of drains. M. evaluate fuel storage tanks or supply systems. N. inspect wastewater treatment systems. O. inspect water treatment systems or water filters. P. inspect water storage tanks, pressure pumps, or bladder tanks. Q. evaluate wait time to obtain hot water at fixtures, or perform testing of any kind to water heater elements. R. evaluate or determine the adequacy of combustion air. S. test, operate, open or close: safety controls, manual stop valves, temperature/pressure-relief valves, control valves, or check valves. T. examine ancillary or auxiliary systems or components, such as, but not limited to, those related to solar water heating and hot water circulation. U. determine the existence or condition of polybutylene plumbing. V. inspect or test for gas or fuel leaks, or indications thereof.

Drain, Waste, & Vent Systems

Material

PVC

11.1 · Leaking Pipe

Master bathroom toilet drain showed signs of leaking. No active leaking was observed at the time of the inspection.
General Information

Fuel Storage & Distribution Systems

Main Gas Shut-off Location

Gas Meter

11.2 · Main Gas Shut-off Location

Gas meter and shut off valve location - exterior, west side of home.
General Information

Hot Water Systems, Controls, Flues & Vents

Capacity

40 Gallons

Location

Basement

Manufacturer

AO Smith

Power Source/Type

Gas

TPR Valve

Temperature relief valve present

11.3 · Manufacturer

Based on the data tag the unit was manufactured in 2015 and is approximately 5 years old.
General Information

11.4 · Corrosion

Corrosion was noted at the pipe fittings at the top of the water heater. Recommend a licensed and qualified plumber repair as needed.
Repair Recommended

11.5 · No Expansion Tank

No expansion tank was present. Expansion tanks allow for the thermal expansion of water in the pipes. These are required in certain areas for new installs. Recommend repair by a licensed and qualified contractor.
Repair Recommended

Main Water Shut-off Device

Location

Basement

11.6 · Location

Main water shut-off
General Information

Water Supply, Distribution Systems & Fixtures

Distribution Material

Copper

Hose Bibs

Hose Bib(s) Leaking

Water Softener

Leaking - No
Loop installed
Plumbing hooked up

Water Supply Material

Galvanized

11.7 · Water Softener

A water softener we present. The water softener was not evaluated as part of the inspection.
Limitations

11.8 · Hose Bibs

One or more hose bibs were observed to leak when operated. Recommend repair by a licensed and qualified contractor.
Repair Recommended

Toilets

Operable

Yes

Toilet loose

No

12 · Doors, Windows & Interior

Doors, Windows & Interior

I. The inspector shall inspect: A. a representative number of doors and windows by opening and closing them; B. floors, walls and ceilings; C. stairs, steps, landings, stairways and ramps; D. railings, guards and handrails; and E. garage vehicle doors and the operation of garage vehicle door openers, using normal operating controls. II. The inspector shall describe: A. a garage vehicle door as manually-operated or installed with a garage door opener. III. The inspector shall report as in need of correction: A. improper spacing between intermediate balusters, spindles and rails for steps, stairways, guards and railings; B. photo-electric safety sensors that did not operate properly; and C. any window that was obviously fogged or displayed other evidence of broken seals. IV. The inspector is not required to: A. inspect paint, wallpaper, window treatments or finish treatments. B. inspect floor coverings or carpeting. C. inspect central vacuum systems. D. inspect for safety glazing. E. inspect security systems or components. F. evaluate the fastening of islands, countertops, cabinets, sink tops or fixtures. G. move furniture, stored items, or any coverings, such as carpets or rugs, in order to inspect the concealed floor structure. H. move suspended-ceiling tiles. I. inspect or move any household appliances. J. inspect or operate equipment housed in the garage, except as otherwise noted. K. verify or certify the proper operation of any pressure-activated auto-reverse or related safety feature of a garage door. L. operate or evaluate any security bar release and opening mechanisms, whether interior or exterior, including their compliance with local, state or federal standards. M. operate any system, appliance or component that requires the use of special keys, codes, combinations or devices. N. operate or evaluate self-cleaning oven cycles, tilt guards/latches, or signal lights. O. inspect microwave ovens or test leakage from microwave ovens. P. operate or examine any sauna, steamgenerating equipment, kiln, toaster, ice maker, coffee maker, can opener, bread warmer, blender, instant hot-water dispenser, or other small, ancillary appliances or devices. Q. inspect elevators. R. inspect remote controls. S. inspect appliances. T. inspect items not permanently installed. U. discover firewall compromises. V. inspect pools, spas or fountains. W. determine the adequacy of whirlpool or spa jets, water force, or bubble effects. X. determine the structural integrity or leakage of pools or spas.

Ceilings

Ceiling Material

Finished Drywall

12.1 · Minor Damage

Typical drywall cracking observed at one or more ceiling locations.
General Information

Doors

12.2 · Water Staining

One or more doors show noticeable water staining, which could lead to further deterioration. Monitor for future repair or replacement by a licensed and qualified contractor.
Repair Recommended

Walls

Wall Material

Drywall

12.3 · Typical Cracks

Typical drywall cracking was observed on one or more walls.
General Information

Windows

12.4 · Damaged

One or more windows had loose, damaged or inoperable hardware. Recommend repair by a licensed and qualified contractor.
Repair Recommended

12.5 · Damaged

Damaged wood was observed at one or more windows. Recommend repair by a licensed and qualified contractor.
Repair Recommended